ePrints Repository

Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial

Mant, J.W.F. and Fitzmaurice, D.A. and Hobbs, F.D.R. and Jowett, S.M. and Murray, E.T. and Holder, R.L. and Davies, M. and Lip, G.Y.H. (2007) Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial. British Medical Journal (BMJ). pp. 380-382. ISSN 0959-8138

Loading
PDF (349Kb)

URL of Published Version: http://www.bmj.com/cgi/content/full/bmj.39227.551713.AEv1

Identification Number/DOI: 10.1136/bmj.39227.551713.AE

Objective To assess the accuracy of general practitioners, practice nurses, and interpretative software in the use of different types of electrocardiogram to diagnose atrial fibrillation.
Design Prospective comparison with reference standard of assessment of electrocardiograms by two independent specialists.

Setting 49 general practices in central England.

Participants 2595 patients aged 65 or over screened for atrial fibrillation as part of the screening for atrial fibrillation in the elderly (SAFE) study; 49 general practitioners and 49 practice nurses.

Interventions All electrocardiograms were read with the Biolog interpretative software, and a random sample of 12 lead, limb lead, and single lead thoracic placement electrocardiograms were assessed by general practitioners and practice nurses independently of each other and of the Biolog assessment.

Main outcome measures Sensitivity, specificity, and positive and negative predictive values.

Results General practitioners detected 79 out of 99 cases of atrial fibrillation on a 12 lead electrocardiogram (sensitivity 80%, 95% confidence interval 71% to 87%) and misinterpreted 114 out of 1355 cases of sinus rhythm as atrial fibrillation (specificity 92%, 90% to 93%). Practice nurses detected a similar proportion of cases of atrial fibrillation (sensitivity 77%, 67% to 85%), but had a lower specificity (85%, 83% to 87%). The interpretative software was significantly more accurate, with a specificity of 99%, but missed 36 of 215 cases of atrial fibrillation (sensitivity 83%). Combining general practitioners' interpretation with the interpretative software led to a sensitivity of 92% and a specificity of 91%. Use of limb lead or single lead thoracic placement electrocardiograms resulted in some loss of specificity.

Conclusions Many primary care professionals cannot accurately detect atrial fibrillation on an electrocardiogram, and interpretative software is not sufficiently accurate to circumvent this problem, even when combined with interpretation by a general practitioner. Diagnosis of atrial fibrillation in the community needs to factor in the reading of electrocardiograms by appropriately trained people

Type of Work:Article
Date:29 June 2007 (Publication)
School/Faculty:Schools (1998 to 2008) > School of Medicine
Department:Department of Primary Care and General Practice
Subjects:R Medicine (General)
Institution:University of Birmingham
Copyright Holders:BMJ Publishing Group Limited
ID Code:63
Refereed:YES
Local Holdings:
Export Reference As : ASCII + BibTeX + Dublin Core + EndNote + HTML + METS + MODS + OpenURL Object + Reference Manager + Refer + RefWorks
Share this item :
QR Code for this page

Repository Staff Only: item control page